An optimal design of a three-layer experimental apparatus where a thin heater is placed between two identical samples is proposed. It allows thermal conductivity and volumetric heat capacity of high-conductivity materials to be estimated when the heating period is finite and the heater heat capacity is not negligible. Once the thermal field within the sample is known and the sensitivity coefficients are computed, a D-optimum criterion is applied in order to minimize the area of the confidence region of the estimates. Three experimental variables (experiment duration, heating duration and sensor location) are investigated for different values of the heater heat capacity. For instance, when it is 5% of the sample heat capacity, the optimal experiment duration is of about 4% longer than that occurring when the heater is neglected. However, the heater heat capacity does not affect the optimal heating duration and the optimal sensor locations.

Optimal Experiment Design for Thermal Property Estimation Using a Boundary Condition of the Fourth Kind with a Time-Limited Heating Period

D'ALESSANDRO Giampaolo
Membro del Collaboration Group
;
DE MONTE Filippo
Membro del Collaboration Group
2019-01-01

Abstract

An optimal design of a three-layer experimental apparatus where a thin heater is placed between two identical samples is proposed. It allows thermal conductivity and volumetric heat capacity of high-conductivity materials to be estimated when the heating period is finite and the heater heat capacity is not negligible. Once the thermal field within the sample is known and the sensitivity coefficients are computed, a D-optimum criterion is applied in order to minimize the area of the confidence region of the estimates. Three experimental variables (experiment duration, heating duration and sensor location) are investigated for different values of the heater heat capacity. For instance, when it is 5% of the sample heat capacity, the optimal experiment duration is of about 4% longer than that occurring when the heater is neglected. However, the heater heat capacity does not affect the optimal heating duration and the optimal sensor locations.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0017931018338493-main.pdf

solo utenti autorizzati

Tipologia: Documento in Versione Editoriale
Licenza: Dominio pubblico
Dimensione 3.19 MB
Formato Adobe PDF
3.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/131826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 8
social impact