Background: Neutral zone (NZ) is a specific area in the oral cavity where muscular opposite forces are null. NZ represents the ideal zone for prosthesis placement. In this study, we compared digital implant planning using conventional technique and using NZ registration through piezography. Methods: Sixty-tree implants were digitally planned. Angular deviation differences between traditional planned and NZ-planned implants were calculated. In addition, interferences with soft tissues (i.e., tongue and cheeks) were evaluated. Results: We observed a significant difference between traditional technique and piezographic approach in terms of implants angulation (p =.003), independent of site. A 4.7% of the planned abutments with traditional technique were placed outside the NZ, causing conflict with soft tissues in the digital model. Conclusions: Compared with traditional technique, piezography allows a significantly different exploitation of the nonconflict area, which potentially translates into better management of soft tissues and improved functionality of the implants.

Neutral zone recording in computer-guided implant prosthesis: A new digital neuromuscular approach

Frascaria M.;Pietropaoli D.;Casinelli M.;Cattaneo R.;Ortu E.;Monaco A.
2019-01-01

Abstract

Background: Neutral zone (NZ) is a specific area in the oral cavity where muscular opposite forces are null. NZ represents the ideal zone for prosthesis placement. In this study, we compared digital implant planning using conventional technique and using NZ registration through piezography. Methods: Sixty-tree implants were digitally planned. Angular deviation differences between traditional planned and NZ-planned implants were calculated. In addition, interferences with soft tissues (i.e., tongue and cheeks) were evaluated. Results: We observed a significant difference between traditional technique and piezographic approach in terms of implants angulation (p =.003), independent of site. A 4.7% of the planned abutments with traditional technique were placed outside the NZ, causing conflict with soft tissues in the digital model. Conclusions: Compared with traditional technique, piezography allows a significantly different exploitation of the nonconflict area, which potentially translates into better management of soft tissues and improved functionality of the implants.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/142978
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact