Compliance with the established exposure limits for the electric field (E-field) induced in the human brain due to low-frequency magnetic field (B-field) induction is demonstrated by numerical dosimetry. The objective of this study is to investigate the dependency of dosimetric compliance assessments on the applied methodology and segmentations. The dependency of the discretization uncertainty (i.e., staircasing and field singularity) on the spatially averaged peak E-field values is first determined using canonical and anatomical models. Because spatial averaging with a grid size of 0.5mm or smaller sufficiently reduces the impact of artifacts regardless of tissue size, it is a superior approach to other proposed methods such as the 99th percentile or smearing of conductivity contrast. Through a canonical model, it is demonstrated that under the same uniform B-field exposure condition, the peak spatially averaged E-fields in a heterogeneous model can be significantly underestimated by a homogeneous model. The frequency scaling technique is found to introduce substantial error if the relative change in tissue conductivity is significant in the investigated frequency range. Lastly, the peak induced E-fields in the brain tissues of five high-resolution anatomically realistic models exposed to a uniform B-field at ICNIRP and IEEE reference levels in the frequency range of 10Hz to 100kHz show that the reference levels are not always compliant with the basic restrictions. Based on the results of this study, a revision is recommended for the guidelines/standards to achieve technically sound exposure limits that can be applied without ambiguity. © 2013 Wiley Periodicals, Inc.

Analysis of human brain exposure to low-frequency magnetic fields: A numerical assessment of spatially averaged electric fields and exposure limits

De Santis V.;
2013-01-01

Abstract

Compliance with the established exposure limits for the electric field (E-field) induced in the human brain due to low-frequency magnetic field (B-field) induction is demonstrated by numerical dosimetry. The objective of this study is to investigate the dependency of dosimetric compliance assessments on the applied methodology and segmentations. The dependency of the discretization uncertainty (i.e., staircasing and field singularity) on the spatially averaged peak E-field values is first determined using canonical and anatomical models. Because spatial averaging with a grid size of 0.5mm or smaller sufficiently reduces the impact of artifacts regardless of tissue size, it is a superior approach to other proposed methods such as the 99th percentile or smearing of conductivity contrast. Through a canonical model, it is demonstrated that under the same uniform B-field exposure condition, the peak spatially averaged E-fields in a heterogeneous model can be significantly underestimated by a homogeneous model. The frequency scaling technique is found to introduce substantial error if the relative change in tissue conductivity is significant in the investigated frequency range. Lastly, the peak induced E-fields in the brain tissues of five high-resolution anatomically realistic models exposed to a uniform B-field at ICNIRP and IEEE reference levels in the frequency range of 10Hz to 100kHz show that the reference levels are not always compliant with the basic restrictions. Based on the results of this study, a revision is recommended for the guidelines/standards to achieve technically sound exposure limits that can be applied without ambiguity. © 2013 Wiley Periodicals, Inc.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/152456
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 53
social impact