The use of pH-sensitive nitroxides, in conjunction with low-frequency EPR, offers a unique opportunity for non-invasive;assessment of pH values (in the range 0 to 14) in living animals. In the present study, we have investigated the potential use of pH-sensitive nitroxide free radicals in conjunction with EPR imaging techniques at low and very low frequencies (280 MHz-2.1 GHz). In particular, vie have measured the hyperfine splitting (hfs) of a pH-sensitive probe at three different EPR frequencies: 280 MHz, 1.1 GHz and 2.1 GHz. We have also developed EPR imaging experiments with phantoms simulating in vivo conditions, using pH-sensitive probes at 280 MHz (spatial-spatial) and 1.1 GHz (spectral-spatial). Finally, we discuss the actual sensitivity/resolution limits of the EPR imaging techniques at low frequencies. Practical applications of this method in the biomedical field are suggested for the continuous and non-invasive localization of pH in vivo.

pH-sensitive imaging by low-frequency EPR: a model study for biological applications

PLACIDI, GIUSEPPE;COLACICCHI, SILVIA;ALECCI, MARCELLO
1998-01-01

Abstract

The use of pH-sensitive nitroxides, in conjunction with low-frequency EPR, offers a unique opportunity for non-invasive;assessment of pH values (in the range 0 to 14) in living animals. In the present study, we have investigated the potential use of pH-sensitive nitroxide free radicals in conjunction with EPR imaging techniques at low and very low frequencies (280 MHz-2.1 GHz). In particular, vie have measured the hyperfine splitting (hfs) of a pH-sensitive probe at three different EPR frequencies: 280 MHz, 1.1 GHz and 2.1 GHz. We have also developed EPR imaging experiments with phantoms simulating in vivo conditions, using pH-sensitive probes at 280 MHz (spatial-spatial) and 1.1 GHz (spectral-spatial). Finally, we discuss the actual sensitivity/resolution limits of the EPR imaging techniques at low frequencies. Practical applications of this method in the biomedical field are suggested for the continuous and non-invasive localization of pH in vivo.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/18262
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 34
social impact