The aim of this study was to compare the positional information transfer accuracy of palatal temporary anchorage devices (TADs) of two different brands of transfer caps: PSM and Leone. Thirty plaster casts of maxillary dental arches were chosen for master models. A couple of Leone TADs were inserted in each master model. For each master model, two analysis models were created: using two transfer caps, Leone and PSM, the impressions were taken, the analogues were connected on the transfer caps, and the casts were poured. Using digital methods and equipment, such as a 3D scanner, a 3D analysis and a comparison of the accuracy of the two transfer caps in transferring the positional information of the TADs was then made. The data obtained were analyzed using the Mann-Whitney U-test at a significance level of alpha = 0.05. PSM transfer caps showed higher error frequency in almost all measurements. Only two measurements had a larger error in the analysis models made with Leone transfer caps. The Mann-Whitney U-test found a significant difference between the error levels of TADs found in the analysis models created with PSM transfer caps. Leone transfer caps showed greater reliability in TADs positional information transmission.

Comparison of the Accuracy of Two Transfer Caps in Positional Transmission of Palatal Temporary Anchorage Devices: An In Vitro Study

Vincenzo Quinzi;Giuseppe Marzo;
2023-01-01

Abstract

The aim of this study was to compare the positional information transfer accuracy of palatal temporary anchorage devices (TADs) of two different brands of transfer caps: PSM and Leone. Thirty plaster casts of maxillary dental arches were chosen for master models. A couple of Leone TADs were inserted in each master model. For each master model, two analysis models were created: using two transfer caps, Leone and PSM, the impressions were taken, the analogues were connected on the transfer caps, and the casts were poured. Using digital methods and equipment, such as a 3D scanner, a 3D analysis and a comparison of the accuracy of the two transfer caps in transferring the positional information of the TADs was then made. The data obtained were analyzed using the Mann-Whitney U-test at a significance level of alpha = 0.05. PSM transfer caps showed higher error frequency in almost all measurements. Only two measurements had a larger error in the analysis models made with Leone transfer caps. The Mann-Whitney U-test found a significant difference between the error levels of TADs found in the analysis models created with PSM transfer caps. Leone transfer caps showed greater reliability in TADs positional information transmission.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/202442
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact