Rising power densities in packaged integrated circuits (ICs) increase the need for noninvasive and mechanism informative failure diagnosis. Conventional lock in thermography (LIT) is typically limited to fundamental amplitude and phase maps for hotspot localization and does not fully exploit the thermal information available during packaged ICs inspection. This work proposes a multi-harmonic LIT method based on electro-thermal feedback driven nonlinear model, which explains the physical origin of higher order harmonics and leverages harmonic amplitude and phase information for defect detection and diagnosis. Experiments on one representative failed packaged ICs specimen show that higher order amplitude maps can improve signal to noise ratio (SNR) and spatial localization accuracy. Under the tested conditions, the 2nd harmonic amplitude map reduces hotspot full width at half maximum (FWHM) by 29.1% and increases SNR by up to 56.2% compared with the conventional LIT amplitude map. We further introduce an effective power law exponent, γm, to characterize the amplitude versus voltage relation and to assist in separating defect and intact regions. Finally, we propose a defect attribute diagnosis method based on higher order harmonic phases. Our theoretical derivation indicates that interconnect related and junction related failures lead to different harmonic phase paths. Therefore, these behaviors can be differentiated noninvasively by analyzing higher order harmonic phases, and this inference is further supported by optical beam induced resistance change (OBIRCH), emission microscopy (EMMI), and focused ion beam (FIB) cross sectional analysis. The proposed method improves spatial localization while adding interpretable mechanism cues for ICs failure analysis.
Multi-harmonic frequency-domain thermography for IC failure diagnosis: electrothermal nonlinearity modeling and phase-path criteria
Sfarra, Stefano;
2026-01-01
Abstract
Rising power densities in packaged integrated circuits (ICs) increase the need for noninvasive and mechanism informative failure diagnosis. Conventional lock in thermography (LIT) is typically limited to fundamental amplitude and phase maps for hotspot localization and does not fully exploit the thermal information available during packaged ICs inspection. This work proposes a multi-harmonic LIT method based on electro-thermal feedback driven nonlinear model, which explains the physical origin of higher order harmonics and leverages harmonic amplitude and phase information for defect detection and diagnosis. Experiments on one representative failed packaged ICs specimen show that higher order amplitude maps can improve signal to noise ratio (SNR) and spatial localization accuracy. Under the tested conditions, the 2nd harmonic amplitude map reduces hotspot full width at half maximum (FWHM) by 29.1% and increases SNR by up to 56.2% compared with the conventional LIT amplitude map. We further introduce an effective power law exponent, γm, to characterize the amplitude versus voltage relation and to assist in separating defect and intact regions. Finally, we propose a defect attribute diagnosis method based on higher order harmonic phases. Our theoretical derivation indicates that interconnect related and junction related failures lead to different harmonic phase paths. Therefore, these behaviors can be differentiated noninvasively by analyzing higher order harmonic phases, and this inference is further supported by optical beam induced resistance change (OBIRCH), emission microscopy (EMMI), and focused ion beam (FIB) cross sectional analysis. The proposed method improves spatial localization while adding interpretable mechanism cues for ICs failure analysis.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.