Flexible sensors are increasingly adopted in biomedical engineering because of their mechanical compliance with soft tissues and their suitability for continuous, non-invasive physiological monitoring. In this context, additive manufacturing enables cost-effective, highly customizable fabrication of such healthcare devices. This work presents a fully three-dimensional (3D)-printed capacitive strain sensor. The device, composed of conductive and dielectric elements, is entirely fabricated through multi-material Fused Deposition Modelling (FDM) and has been experimentally characterized under controlled bending conditions. Capacitance measurements yield an effective relative permittivity of 5.7 for the printed Polyethylene Terephthalate Glycol (PETG) dielectric layer. The sensor exhibits a monotonic variation of capacitance with increasing flexure, with an average sensitivity of 0.18 pF/mm. Furthermore, over a 20-45 °C temperature interval, the sensor shows a 35.8% capacitance variation. These results demonstrate the feasibility of the low-cost, fully additively manufactured capacitive sensor, as both a pressure and a strain sensor, for wearable healthcare applications.
A Flexible Capacitive Sensor for Biomedical Applications
Olivieri, Riccardo;Barile, Gianluca;Stornelli, Vincenzo;Ferri, Giuseppe
2026-01-01
Abstract
Flexible sensors are increasingly adopted in biomedical engineering because of their mechanical compliance with soft tissues and their suitability for continuous, non-invasive physiological monitoring. In this context, additive manufacturing enables cost-effective, highly customizable fabrication of such healthcare devices. This work presents a fully three-dimensional (3D)-printed capacitive strain sensor. The device, composed of conductive and dielectric elements, is entirely fabricated through multi-material Fused Deposition Modelling (FDM) and has been experimentally characterized under controlled bending conditions. Capacitance measurements yield an effective relative permittivity of 5.7 for the printed Polyethylene Terephthalate Glycol (PETG) dielectric layer. The sensor exhibits a monotonic variation of capacitance with increasing flexure, with an average sensitivity of 0.18 pF/mm. Furthermore, over a 20-45 °C temperature interval, the sensor shows a 35.8% capacitance variation. These results demonstrate the feasibility of the low-cost, fully additively manufactured capacitive sensor, as both a pressure and a strain sensor, for wearable healthcare applications.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


