This work investigates the performance of 3D-printed dry electrodes designed for physiological signal acquisition, focusing on the variation of their electrical behavior with material and geometry. Four electrode designs were fabricated through Fused Deposition Modeling (FDM) using a tool-changer architecture and two conductive filaments: carbon-based Protopasta and copper-based Electrifi. Electrical impedance was characterized over a wide frequency range using an impedance analyzer. Protopasta electrodes exhibit a predominantly resistive response at low frequencies, with impedance values ranging from approximately 70 Ω to 225 Ω at 1 Hz. At higher frequencies the impedance decreases significantly (down to about 22-140 Ω at 1 MHz), indicating the contribution of parasitic effects. In contrast, Electrifi electrodes show much lower impedance values, ranging from approximately 0.6 Ω to 2.6 Ω at low frequency, remaining nearly constant up to tens of kilohertz and increasing to about 2-3 Ω at 1 MHz, where inductive effects become dominant. Geometrical variations also influenced the measured impedance: electrodes with flat contact surfaces exhibit lower resistance, while designs with protruding contact tips show slightly higher impedance. These results confirm that additive manufacturing enables the fabrication of customizable conductive electrodes with predictable electrical properties, providing a basis for further optimization of 3D-printed electrodes for wearable and personalized biomedical signal acquisition.
A study on Impedance Behavior of 3D-Printed Electrodes for Physiological Signal Acquisition
Montaldi, Elisa;Olivieri, Riccardo;Barile, Gianluca;Colaiuda, Davide;Ferri, Giuseppe;Stornelli, Vincenzo
2026-01-01
Abstract
This work investigates the performance of 3D-printed dry electrodes designed for physiological signal acquisition, focusing on the variation of their electrical behavior with material and geometry. Four electrode designs were fabricated through Fused Deposition Modeling (FDM) using a tool-changer architecture and two conductive filaments: carbon-based Protopasta and copper-based Electrifi. Electrical impedance was characterized over a wide frequency range using an impedance analyzer. Protopasta electrodes exhibit a predominantly resistive response at low frequencies, with impedance values ranging from approximately 70 Ω to 225 Ω at 1 Hz. At higher frequencies the impedance decreases significantly (down to about 22-140 Ω at 1 MHz), indicating the contribution of parasitic effects. In contrast, Electrifi electrodes show much lower impedance values, ranging from approximately 0.6 Ω to 2.6 Ω at low frequency, remaining nearly constant up to tens of kilohertz and increasing to about 2-3 Ω at 1 MHz, where inductive effects become dominant. Geometrical variations also influenced the measured impedance: electrodes with flat contact surfaces exhibit lower resistance, while designs with protruding contact tips show slightly higher impedance. These results confirm that additive manufacturing enables the fabrication of customizable conductive electrodes with predictable electrical properties, providing a basis for further optimization of 3D-printed electrodes for wearable and personalized biomedical signal acquisition.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.