The need for accurate determination of the temperature of vital components during the development of new gas turbines has made it important to investigate error in thermocouple measurement of surfaec measurement. a model equipped with thermocouples installed by the most commomly-used technologies has been constructed and tested to evaluate error in measurement.
Evaluation of Errors Associated with Different Sheated Thermo-couple Installation Methods in Gas Turbine Components Temperature Measurement
D'EMILIA, Giulio;
1986-01-01
Abstract
The need for accurate determination of the temperature of vital components during the development of new gas turbines has made it important to investigate error in thermocouple measurement of surfaec measurement. a model equipped with thermocouples installed by the most commomly-used technologies has been constructed and tested to evaluate error in measurement.File in questo prodotto: