The need for accurate determination of the temperature of vital components during the development of new gas turbines has made it important to investigate error in thermocouple measurement of surfaec measurement. a model equipped with thermocouples installed by the most commomly-used technologies has been constructed and tested to evaluate error in measurement.
Titolo: | Evaluation of Errors Associated with Different Sheated Thermo-couple Installation Methods in Gas Turbine Components Temperature Measurement |
Autori: | |
Data di pubblicazione: | 1986 |
Rivista: | |
Abstract: | The need for accurate determination of the temperature of vital components during the development of new gas turbines has made it important to investigate error in thermocouple measurement of surfaec measurement. a model equipped with thermocouples installed by the most commomly-used technologies has been constructed and tested to evaluate error in measurement. |
Handle: | http://hdl.handle.net/11697/3335 |
Appare nelle tipologie: | 1.1 Articolo in rivista |
File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.