A deterministic algorithm aiming at reduction of harmonic content in three phase, five-level cascaded inverters is proposed. The procedure starts from a non-linear system consisting of disequations and, using Chebyshev polynomials and Waring’s formula, for any assigned modulation index computes those switching angles α1 and α2 reducing harmonics amplitude such as to fulfill grid code specifications. Simulation and experi- mental results demonstrate the achievable results.
A deterministic harmonics mitigation technique for five-level inverters
BUCCELLA, CONCETTINA;CECATI, Carlo;CIMORONI, MARIA GABRIELLA;
2014-01-01
Abstract
A deterministic algorithm aiming at reduction of harmonic content in three phase, five-level cascaded inverters is proposed. The procedure starts from a non-linear system consisting of disequations and, using Chebyshev polynomials and Waring’s formula, for any assigned modulation index computes those switching angles α1 and α2 reducing harmonics amplitude such as to fulfill grid code specifications. Simulation and experi- mental results demonstrate the achievable results.File in questo prodotto: