It is shown that the high-frequency (skin effect) internal resistance and internal inductive reactance are not equal for conductors of rectangular cross section as they are for conductors of circular cross section such as wires. A numerical method is used to demonstrate this and to show the errors incurred in using this approach.

Internal impedance of conductors of rectangular cross section

ANTONINI, GIULIO;ORLANDI, Antonio;
1998-01-01

Abstract

It is shown that the high-frequency (skin effect) internal resistance and internal inductive reactance are not equal for conductors of rectangular cross section as they are for conductors of circular cross section such as wires. A numerical method is used to demonstrate this and to show the errors incurred in using this approach.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/38174
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact