This paper presents an improved cavity model for the analysis of transient voltage bounces in power/ground structures. Firstly, accurate models from DC to the maximum frequency of interest are adopted to describe conductor and dielectric losses; secondly, the Vector Fitting technique is used to generate a rational model which is converted in a state-space macromodel, well suited for transient analysis. The numerical results demonstrate the high efficiency and good accuracy of the proposed method.

An improved cavity model for the analysis of the voltage bounce in power-bus structures

ANTONINI, GIULIO;
2007-01-01

Abstract

This paper presents an improved cavity model for the analysis of transient voltage bounces in power/ground structures. Firstly, accurate models from DC to the maximum frequency of interest are adopted to describe conductor and dielectric losses; secondly, the Vector Fitting technique is used to generate a rational model which is converted in a state-space macromodel, well suited for transient analysis. The numerical results demonstrate the high efficiency and good accuracy of the proposed method.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/39060
Citazioni