"This paper deals with the development of an analog. electronic wattmeter based on a high-accuracy electronic fourquadrant. multiplier and appropriate amplifying and averaging. circuits. The proposed instrument presents a simple design and. is constructed using commercially available components. Its. main advantage is that it can be integrated with the signal. conditioning circuit, obtaining low cost, high resolution, and. reduced dimensions. It can measure in circuits with very low. power factors and nonsinusoidal waveforms. The implemented. prototype is a portable laboratory instrument, integrated with a. digital system capable of processing the signals, and displaying. the main parameters of both electric power and energy. It has. been designed to easily integrate the main blocks in that either. industrial or civil equipment requiring the power measurement. for monitoring or control purposes. A Fluke 6100A power. standard is used to calibrate the wattmeter over a wide range. of current magnitudes and widths and at power factors down to. 0.02; several results are reported and discussed."

Embedded Power and Energy Measurement System Based on an Analog Multiplier

BUCCI, Giovanni;FIORUCCI, EDOARDO;Ciancetta F;
2013-01-01

Abstract

"This paper deals with the development of an analog. electronic wattmeter based on a high-accuracy electronic fourquadrant. multiplier and appropriate amplifying and averaging. circuits. The proposed instrument presents a simple design and. is constructed using commercially available components. Its. main advantage is that it can be integrated with the signal. conditioning circuit, obtaining low cost, high resolution, and. reduced dimensions. It can measure in circuits with very low. power factors and nonsinusoidal waveforms. The implemented. prototype is a portable laboratory instrument, integrated with a. digital system capable of processing the signals, and displaying. the main parameters of both electric power and energy. It has. been designed to easily integrate the main blocks in that either. industrial or civil equipment requiring the power measurement. for monitoring or control purposes. A Fluke 6100A power. standard is used to calibrate the wattmeter over a wide range. of current magnitudes and widths and at power factors down to. 0.02; several results are reported and discussed."
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/88751
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 12
social impact