Energy consumption of buildings could be significantly reduced by improving the efficiency of the envelope. Currently, the estimation of the energy performance of existing buildings requires the knowledge of the overall heat transfer coefficient (U-value) of the walls. U-values can be calculated through a theoretical approach, knowing the thermal conductivity and thickness of each material that constitutes the wall stratigraphy, from project data or coring. Alternatively, U-values can be obtained experimentally, through the ISO recommended heat flow meter measurements. Although generally accepted, the heat flow meter method suffers from some disadvantages. Recently, an alternative approach based on infrared thermography (IRT) has been proposed for in situ measurements. Main advantages of this new approach are non invasivity and the possibility of inspecting relatively large areas in real time. In this paper, after a brief description of the state of the art in the field of U-value measurement by IRT, a case study is described. In particular, the results obtained by IRT on an existing building are compared with U-values given by the standard ISO calculation and heat flow meter measurements; advantages and limitations of the new method are outlined. Some suggestions for a successful exploiting of the IRT approach are also given.

Quantitative thermography for the estimation of the U-value: state of the art and a case study

I. Nardi
;
S. Sfarra;AMBROSINI, DARIO
2014-01-01

Abstract

Energy consumption of buildings could be significantly reduced by improving the efficiency of the envelope. Currently, the estimation of the energy performance of existing buildings requires the knowledge of the overall heat transfer coefficient (U-value) of the walls. U-values can be calculated through a theoretical approach, knowing the thermal conductivity and thickness of each material that constitutes the wall stratigraphy, from project data or coring. Alternatively, U-values can be obtained experimentally, through the ISO recommended heat flow meter measurements. Although generally accepted, the heat flow meter method suffers from some disadvantages. Recently, an alternative approach based on infrared thermography (IRT) has been proposed for in situ measurements. Main advantages of this new approach are non invasivity and the possibility of inspecting relatively large areas in real time. In this paper, after a brief description of the state of the art in the field of U-value measurement by IRT, a case study is described. In particular, the results obtained by IRT on an existing building are compared with U-values given by the standard ISO calculation and heat flow meter measurements; advantages and limitations of the new method are outlined. Some suggestions for a successful exploiting of the IRT approach are also given.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/9969
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 42
social impact