INTRODUCTION: Orthodontic treatment of palatally impacted maxillary canines raises many difficulties; to minimize complications, careful planning of orthodontic extrusion and the use of physiologic force are crucial. The aim of this study was to quantitatively evaluate a simple and reproducible system for orthodontic extrusion of impacted canines that can provide the correct amount of force.METHODS: Ten specimens were constructed, consisting of a cantilever made with a 0.6-mm or 0.7-mm stainless steel wire modeled around a transpalatal bar with 3, 5, or 7 loops in the shape of a helical torsion spring. A mechanical testing machine was used to measure the force produced by the cantilever at 3, 6, 9, 12, and 15 mm of activation.RESULTS: The force values ranged from 1.24 ± 0.13 N for the 0.7-mm wire with 3 loops to 0.48 ± 0.04 N for the 0.6-mm wire with 7 loops. The forces measured for the 0.6-mm wire with 3 loops and the 0.7-mm wire with 7 loops were similar at 15 mm of deflection.CONCLUSIONS: The proposed system has a simple and robust design, is easy to construct and manage, and can provide the desired amount of force by changing the wire diameter and number of loops.

Predictable method to deliver physiologic force for extrusion of palatally impacted maxillary canines

Tepedino, Michele;Chimenti, Claudio;Masedu, Francesco;IANCU POTRUBACZ, Maciej
2018-01-01

Abstract

INTRODUCTION: Orthodontic treatment of palatally impacted maxillary canines raises many difficulties; to minimize complications, careful planning of orthodontic extrusion and the use of physiologic force are crucial. The aim of this study was to quantitatively evaluate a simple and reproducible system for orthodontic extrusion of impacted canines that can provide the correct amount of force.METHODS: Ten specimens were constructed, consisting of a cantilever made with a 0.6-mm or 0.7-mm stainless steel wire modeled around a transpalatal bar with 3, 5, or 7 loops in the shape of a helical torsion spring. A mechanical testing machine was used to measure the force produced by the cantilever at 3, 6, 9, 12, and 15 mm of activation.RESULTS: The force values ranged from 1.24 ± 0.13 N for the 0.7-mm wire with 3 loops to 0.48 ± 0.04 N for the 0.6-mm wire with 7 loops. The forces measured for the 0.6-mm wire with 3 loops and the 0.7-mm wire with 7 loops were similar at 15 mm of deflection.CONCLUSIONS: The proposed system has a simple and robust design, is easy to construct and manage, and can provide the desired amount of force by changing the wire diameter and number of loops.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11697/122573
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 13
social impact