The x-rays are produced by high voltage discharge applied inside plasma source interaction chamber; the control circuit system of high voltage is composed of a power supply and a LC-inverter. The goal of the project is based on the production of x-rays by a plasma to increase the efficiency of a classic x-ray tube with hot filament. Preliminary results of high energy x-rays emission, the layout and simulation with p-spice of the high voltage system are presented
High energy X-ray emission driven by high voltage circuit system
PALLADINO, Libero
2014-01-01
Abstract
The x-rays are produced by high voltage discharge applied inside plasma source interaction chamber; the control circuit system of high voltage is composed of a power supply and a LC-inverter. The goal of the project is based on the production of x-rays by a plasma to increase the efficiency of a classic x-ray tube with hot filament. Preliminary results of high energy x-rays emission, the layout and simulation with p-spice of the high voltage system are presentedFile in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.